Four performance considerations geothermal floor quality

The geothermal floor is not thicker and warmer. The floor that is more suitable for geothermal heating should be made of laminate flooring and parquet.

The geothermal floor must have the "four good" requirements of good thermal conductivity, good thermal stability, good environmental performance and good deformation resistance. The heat from the ground is transmitted to the surface through the floor, and there is bound to be heat loss. The ideal floor can minimize these losses. Therefore, in order to reduce the loss of thermal energy and reduce the heating operation and maintenance expenses, the floor heating floor must be "selected thin and not thick".

Although merchants claim to be available for geothermal. But in fact, according to experts, 55% of this can not be used for heating systems, 25% can be used for floor heating, but the effect is not ideal, only 20% is dedicated geothermal floor. Therefore, experts remind consumers to pay attention to some misleading statements, such as the “thicker the better the wooden floor”, the thicker the more insulation, the special geothermal floor has a foam pad and aluminum foil on the back, and the box is printed on the box. The "warm room dedicated" is the geothermal floor and so on. I don’t know if these arguments are unreasonable. They only affect the ground heat dissipation. The geothermal heating meets the characteristics of the human body’s “warm heads and cool heads”, and the geothermal heating eliminates the heating pipes and radiators in the room, which is more conducive to the layout and beauty of the living room. This way is recognized and accepted by more and more people. In the end, how to choose geothermal floor? Due to the special nature of geothermal heating, the requirements for the floor are very strict. Therefore, in addition to meeting the conventional quality indicators, the geothermal floor must meet the four characteristics. The citizens who need geothermal heating can stare. Tight.

In addition, the floor quality pays attention to "three-point floor, seven-point installation", while the professional geothermal floor installation standard is higher, so it is best to provide professional installation by the manufacturer to avoid self-installation by the construction team.

1, excellent thermal conductivity and heat dissipation

Wood and bamboo are good natural materials. The heat from the ground is transmitted to the surface through the floor. There is bound to be heat loss. The ideal floor can minimize these losses. Therefore, in order to reduce the loss of thermal energy and reduce the heating operation and maintenance expenses, the floor heating floor must be "selected thin and not thick". Choose from multi-layer solid wood, bamboo flooring and laminate flooring with a thickness of no more than 8 mm and a maximum of 10 mm.

2, material stability is better

The use environment of geothermal floor is complicated, especially in the northern part of the country. The ground in the non-heating season is subject to various moisture, and the floor temperature of the heating is suddenly increased. The floor must withstand the double changes of “temperature” and “humidity”. Therefore, the geothermal floor must be purchased with good material stability, such as laminate flooring, multi-layer solid wood flooring, and bamboo flooring.

3, moisture and heat resistance is strong

The integrated composite floor should use adhesive, and the adhesive should meet the three indicators of environmental protection, bonding strength, high temperature and high humidity aging. Especially for the geothermal floor, it is necessary to pass the experiments of high humidity resistance and low temperature resistance. If ordinary adhesives are used, the environmental protection index, moisture resistance, aging resistance and expansion ratio cannot meet the standard. Therefore, when consumers are shopping, it is very necessary to check the product report and inspection report of the merchant.

4, wear resistance should last

Since the geothermal floor should be thin and not thick, the composite surface layer is generally 0.3-0.6 mm. The wear resistance of the main surface layer is higher than the traditional index.

The geothermal floor is not thicker and warmer. The floor that is more suitable for geothermal heating should be made of laminate flooring and parquet.

The geothermal floor must have the "four good" requirements of good thermal conductivity, good thermal stability, good environmental performance and good deformation resistance. The heat from the ground is transmitted to the surface through the floor, and there is bound to be heat loss. The ideal floor can minimize these losses. Therefore, in order to reduce the loss of thermal energy and reduce the heating operation and maintenance expenses, the floor heating floor must be "selected thin and not thick".

Although merchants claim to be available for geothermal. But in fact, according to experts, 55% of this can not be used for heating systems, 25% can be used for floor heating, but the effect is not ideal, only 20% is dedicated geothermal floor. Therefore, experts remind consumers to pay attention to some misleading statements, such as the “thicker the better the wooden floor”, the thicker the more insulation, the special geothermal floor has a foam pad and aluminum foil on the back, and the box is printed on the box. The "warm room dedicated" is the geothermal floor and so on. I don't know if these arguments are unreasonable, they only affect the heat dissipation on the ground. Cleaning is an important step to ensure the health of the living environment. When the floor has been cracked, it should be cleaned to prevent the accumulation of dirt.

When cleaning the floor, focus on vacuuming the dust and debris in the cracked part. If the accumulated dirt cannot be sucked out, or where the corners are difficult to clean, you can use a small brush to clean the floor cleaning agent, or you can directly apply the floor. Clean the disinfectant and pour it on the rag.

The traditional installation method of wooden floor adopts the keel method. There is an overhead layer between the floor and the floor. The water in the keel and the liquid such as beverages and milk that are infiltrated when it is not volatile can easily breed bacteria and insects.

The new adhesive installation method and metal keel installation method can avoid the disadvantages of the installation method of the wooden keel. The adhesive method uses the environmentally-friendly floor glue to directly stick the floor to the concrete floor, which can eliminate the dusty insects under the floor. space. However, it is forbidden to fix the keel with cement to prevent the floor from being deformed by moisture.


An electric planer is a power tool with a rotating blade drum; it is designed for the chip-re-moving treatment of mainly wood or plastic surfaces. The Electric Planer is similar in design, handing and performance to the conventional and generally well knows manual planer. The high rotational speed of the universal motor is transmitted to the blade drum by an elastic belt drive.